Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 341
Filtrar
1.
Sci Rep ; 14(1): 8006, 2024 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580778

RESUMO

The 50-km ultra-marathon is a popular race distance, slightly longer than the classic marathon distance. However, little is known about the country of affiliation and age of the fastest 50-km ultra-marathon runners and where the fastest races are typically held. Therefore, this study aimed to investigate a large dataset of race records for the 50-km distance race to identify the country of affiliation and the age of the fastest runners as well as the locations of the fastest races. A total of 1,398,845 50-km race records (men, n = 1,026,546; women, n = 372,299) were analyzed using both descriptive statistics and advanced regression techniques. This study revealed significant trends in the performance of 50-km ultra-marathoners. The fastest 50-km runners came from African countries, while the fastest races were found to occur in Europe and the Middle East. Runners from Ethiopia, Lesotho, Malawi, and Kenya were the fastest in this race distance. The fastest 50-km racecourses, providing ideal conditions for faster race times, are in Europe (Luxembourg, Belarus, and Lithuania) and the Middle East (Qatar and Jordan). Surprisingly, the fastest ultra-marathoners in the 50-km distance were found to fall into the age group of 20-24 years, challenging the conventional belief that peak ultra-marathon performance comes in older age groups. These findings contribute to a better understanding of the performance models in 50-km ultra-marathons and can serve as valuable insights for runners, coaches, and race organizers in optimizing training strategies and racecourse selection.


Assuntos
Desempenho Atlético , Corrida de Maratona , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , População da África Oriental , Quênia , Resistência Física , Distribuição por Idade
2.
Ann Intern Med ; 177(3): eG230014, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38467000
3.
PLoS One ; 19(3): e0299475, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38483945

RESUMO

Using a prospective observational design, this study investigated the hypothesis that competing in the Suffolk Back Yard Ultra-marathon, would result in impaired cognitive performance and examined whether pre-race sleep patterns could mitigate this. Fifteen runners (1 female) volunteered to undertake this study and eleven males were included in the final analysis. Before the race and after withdrawal participants completed the following cognitive performance tasks: 2 Choice Reaction Time (2CRT), Stroop, and the Tower Puzzle. Pre-race sleep strategies were subjectively recorded with a 7-day sleep diary. Following race withdrawal, reaction time increased (Δ 77±68 ms; p = 0.004) in the 2CRT and executive function was impaired in the Stroop task (Interference score Δ -4.3±5.6 a.u.; p = 0.028). Decision making was not affected in the Tower Puzzle task. There was a significant correlation between the pre-race 7-day average sleep scores and both 2CRT Δ throughput (r = 0.61; p = 0.045) and 2CRT Δ RT (r = -0.64; p = 0.034). This study supports the hypothesis that running an ultra-marathon, which includes at least one night of sleep deprivation, impairs cognitive performance and provides novel evidence suggesting good sleep quality, in the week prior to an ultra-marathon, could minimise these effects.


Assuntos
Corrida de Maratona , Privação do Sono , Feminino , Humanos , Masculino , Cognição , Esforço Físico , Sono
4.
Medicina (Kaunas) ; 60(2)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38399506

RESUMO

Background and Objectives: Pacing analyses for increasingly popular long-distance running disciplines have been in researchers' spotlight for several years. In particular, assessing pacing variability in long-distance running was hardly achievable since runners must repeat long-running trials for several days. Potential solutions for these problems could be multi-stage long-distance running disciplines. Therefore, this study aimed to assess the long-distance running variability as well as the reliability, validity, and sensitivity of the variables often used for pacing analyses. Materials and Methods: This study collected the split times and finish times for 20 participants (17 men and three women; mean age 55.5 years ± 9.5 years) who completed the multiday marathon running race (five marathons in 5 days), held as part of the Bretzel Ultra Tri in Colmar, France, in 2021. Seven commonly used pacing variables were subsequently calculated: Coefficient of variation (CV), Change in mean speed (CS), Change in first lap speed (CSF), Absolute change in mean speed (ACS), Pace range (PR), Mid-race split (MRS), and First 32 km-10 km split (32-10). Results: Multi-stage marathon running showed low variability between days (Intraclass correlation coefficient (ICC) > 0.920), while only the CV, ACS, and PR variables proved to have moderate to good reliability (0.732 < ICC < 0.785). The same variables were also valid (r > 0.908), and sensitive enough to discern between runners of different performance levels (p < 0.05). Conclusions: Researchers and practitioners who aim to explore pacing in long-distance running should routinely utilize ACS, CV, and PR variables in their analyses. Other examined variables, CS, CSF, MRS, and 32-10, should be used cautiously. Future studies might try to confirm these results using different multi-stage event's data as well as by expanding sensitivity analysis to age and gender differences.


Assuntos
Desempenho Atlético , Corrida , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Resistência Física , Corrida de Maratona , Reprodutibilidade dos Testes , Fatores de Tempo
5.
Int J Sports Physiol Perform ; 19(4): 412-416, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38215736

RESUMO

PURPOSE: Ultramarathon running has gained popularity over several decades. Although there has been considerable research on training for other running events, from the 100-m to the marathon at 26.2 miles (42.2 km), there is little evidence on best practices for ultramarathons, where distances potentially exceed 100 miles (160.9 km). METHODS: In this case study, we examine the training regimen of an elite ultramarathon runner who broke 8 world records in 2021 and 2022, including the 24-hour run in which he ran 319.6 km in September 2022. Training data from December 28, 2020, to September 17, 2022, were collected from the Strava application database (recorded on Coros watch) and analyzed using Microsoft Excel and Tableau. RESULTS: Our subject completed 5 training blocks, with volume per training block averaging 172.1 to 263 km/wk. Peak running volume per training block occurred on average 3.2 weeks out from races and reached a maximum of 378 km/wk. Recovery was emphasized the week following a race, with less running (19 km/wk) and more cross-training. Interval-type workouts (1- to 10-km repeats) were completed throughout training blocks. The average pace during the 24-hour world-record run was 4 minutes and 30 seconds per kilometer (4:30/km), closely matching the overall average training pace. CONCLUSIONS: These findings suggest that training for ultramarathon races should include high-volume running at varied paces and intensity with cross-training to avoid injuries. We hope that this evidence helps athletes understand how to prepare for these ultraendurance events.


Assuntos
Resistência Física , Corrida , Masculino , Humanos , Corrida de Maratona , Atletas
6.
BMC Musculoskelet Disord ; 25(1): 77, 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38245696

RESUMO

OBJECTIVE: To analyze the changes of plantar pressure in amateur marathon runners with flexor halluics longus (FHL) tendon injury using the Medtrack-Gait plantar pressure measurement system, and to explore whether the plantar pressure data can be used as an index for the diagnosis of injury. METHODS: A total of 39 healthy amateur marathon runners without any ankle joint symptoms were recruited. Dynamic and static plantar pressure data were measured using the pressure plate of Medtrack-Gait. According to MRI imaging findings, whether the FHL tendon was injured or not was judged, and the dynamic and static data were divided into the injury group and control group. The data with statistically significant differences between the two groups were used to make the receiver operating characteristic (ROC) curve. RESULT: The maximum contact area (PA) of the first metatarsal(M1) region, the maximum load-bearing peak value (PW) and the time pressure integral (PMPTI) of the second metatarsal(M2) region in the injury group were lower than those in the control group, respectively (P < 0.05). The maximum contact area (PA) of the fifth metatarsal(M5) region was higher than that in the control group (P < 0.05). The area under curve (AUC) value of the ROC curve of the PA of M1 region, the PW and PMPTI of M2 region were statistically (P < 0.05). CONCLUSION: FHL tendon injury resulted in decreased PA in M1, decreased PW and PMPTI in M2, and increased PA in the M5 region, suggesting that FHL tendon injury resulted in a force shift from the medial to the lateral side of the foot. The PA of M1, PW and PMPTI of M2 have certain diagnostic value for early FHL injury in amateur marathon runners.


Assuntos
Corrida de Maratona , Traumatismos dos Tendões , Humanos , Transferência Tendinosa/métodos , Tendões , Pé/diagnóstico por imagem , Traumatismos dos Tendões/diagnóstico por imagem
7.
J Therm Biol ; 119: 103781, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38232473

RESUMO

Ice slurry ingestion during prolonged exercises may improve performance in hot environments; however, the ideal amount and timing of ingestion are still uncertain. We determined whether ad libitum ice slurry ingestion influences physiological and perceptual variables and half-marathon performance while comparing the effects of the amount and moment of ingestion between ice slurry and water at 37 °C. Ten trained participants (28 ± 2 years; mean and SD) were required to run two half marathons while consuming either ice slurry (-1 °C; Ad-1) or water (37 °C; 37 CE) ad libitum. They then performed two other half marathons where, during one, they were required to ingest an amount of water equivalent to the amount consumed during the Ad-1 trial (Pro37), and in the other, to ingest ice slurry in the amount consumed during the 37 CE trial (Pro-1). During the half marathons, dry-bulb temperature and relative humidity were controlled at 33.1 ± 0.3 °C and 60 ± 3%, respectively. Ad-1 ingestion (349.6 ± 58.5 g) was 45% less than 37 CE ingestion (635.5 ± 135.8 g). Physical performance, heart rate, perceived exertion, body temperatures, and thermal perception were not influenced by the temperature or amount of beverage ingestion. However, a secondary analysis suggested that lower beverage ingestion was associated with improved performance (Ad-1 + Pro37 vs. 37 CE + Pro-1: -4.0 min, Cohen's d = 0.39), with a significant relationship between lower beverage ingestion and faster running time (b = 0.02, t = 4.01, p < 0.001). In conclusion, ice slurry ingestion does not affect performance or physiological or perceptual variables during a half marathon in a hot environment. Preliminary evidence suggests that lower beverage ingestion (ice slurry or warm water) is associated with improved performance compared to higher ingestion.


Assuntos
Temperatura Corporal , Água , Humanos , Temperatura Corporal/fisiologia , Regulação da Temperatura Corporal/fisiologia , Gelo , Corrida de Maratona , Temperatura Alta , Ingestão de Alimentos
8.
J Appl Physiol (1985) ; 136(1): 158-176, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38059288

RESUMO

Carbohydrate (CHO) availability sustains high metabolic demands during prolonged exercise. The adequacy of current CHO intake recommendations, 30-90 g·h-1 dependent on CHO mixture and tolerability, to support elite marathon performance is unclear. We sought to scrutinize the current upper limit recommendation for exogenous CHO intake to support modeled sub-2-h marathon (S2M) attempts across elite male and female runners. Male and female runners (n = 120 each) were modeled from published literature with reference characteristics necessary to complete a S2M (e.g., body mass and running economy). Completion of a S2M was considered across a range of respiratory exchange rates, with maximal starting skeletal muscle and liver glycogen content predicted for elite male and female runners. Modeled exogenous CHO bioavailability needed for male and female runners were 93 ± 26 and 108 ± 22 g·h-1, respectively (P < 0.0001, d = 0.61). Without exogenous CHO, males were modeled to deplete glycogen in 84 ± 7 min, females in 71 ± 5 min (P < 0.0001, d = 2.21) despite higher estimated CHO oxidation rates in males (5.1 ± 0.5 g·h-1) than females (4.4 ± 0.5 g·h-1; P < 0.0001, d = 1.47). Exogenous CHO intakes ≤ 90 g·h-1 are insufficient for 65% of modeled runners attempting a S2M. Current recommendations to support marathon performance appear inadequate for elite marathon runners but may be more suitable for male runners in pursuit of a S2M (56 of 120) than female runners (28 of 120).NEW & NOTEWORTHY This study scrutinizes the upper limit of exogenous carbohydrate (CHO) recommendations for elite male and female marathoners by modeling sex-specific needs across an extreme metabolic challenge lasting ∼2 h, a sub-2-h marathon. Contemporary nutritional guidelines to optimize marathon performance appear inadequate for most elite marathon runners but appear more appropriate for males over their female counterparts. Future research examining possible benefits of exogenous CHO intakes > 90 g·h-1 should prioritize female athlete study inclusion.


Assuntos
Corrida de Maratona , Corrida , Humanos , Masculino , Feminino , Estado Nutricional , Corrida/fisiologia , Exercício Físico , Glicogênio , Resistência Física/fisiologia
9.
Gait Posture ; 108: 44-49, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37980834

RESUMO

BACKGROUND: Despite the increasing popularity of endurance running competitions among adolescent runners, there is currently limited information regarding expected biomechanical changes across the duration of a long-distance running event, and the relationship between young runners' biomechanics and running performance. Wearable technology offers an ecological means to continuously assess runners' biomechanical data during outdoor running competitions. RESEARCH QUESTION: Do adolescent athletes adopt changes in sensor-derived biomechanics throughout a marathon race, and are there relationships between race performance and biomechanical features among young marathoners? METHODS: Fourteen high-school aged runners (9 M, 5 F; age: 16 ± 1 years, height: 170.8 ± 7.5 cm; mass: 63.6 ± 9.4 kg) wore lace-mounted sensors to record step-by-step biomechanics during a marathon race. Official race segment completion times were extracted across 5 race segments (5-K, 15-K, Half Marathon [21.1-K], 35-K, Marathon [42.2-K]). Within-participant repeated measures of covariance (pace) were conducted to assess changes in biomechanics across the race, with Bonferroni post-hoc comparisons. Pearson's r correlations were performed to assess the relationship between race finish times and biomechanics. RESULTS: Pace was significantly slower (p-range: 0.002-0.005), contact times significantly longer, and stride lengths significantly shorter in the final segment compared to middle segments (p-range: 0.003-0.004). The rate of shock accumulation was significantly higher in the final race segment compared to the first three segments (p-range: 0.001-0.002). Moderate relationships existed between finish times and pace (r = -0.63), stride length (r = -0.62), and contact time (r = 0.51). SIGNIFICANCE: Adolescent runners altered their gait patterns in the final marathon segment compared to earlier segments. Spatiotemporal measures were moderately correlated with race finish times, suggesting a link between faster run pace, increased stride lengths, and reduced contact time for improved running performance during an endurance race.


Assuntos
Corrida , Dispositivos Eletrônicos Vestíveis , Adolescente , Humanos , Fenômenos Biomecânicos , Marcha , Corrida de Maratona , Masculino , Feminino
11.
J Sci Med Sport ; 27(1): 20-24, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37919145

RESUMO

This article presents a unique exercise-associated collapse case during a marathon, highlighting the significance of evidence-based management for athletes on field. The patient, a 61-year-old experienced runner, collapsed near the finish line of the Milano City Marathon. He was aided immediately with CPR and AED. After excluding, through validated algorithms, common and life-threatening causes of collapse, the patient was transferred to hospital. The patient underwent diagnostic procedures, including CT and MRI scans, and hormonal tests that revealed pituitary hemorrhage and underlying coronary artery disease. Follow-up assessments and personalized care were instrumental in the patient's successful recovery and safe return to exercise.


Assuntos
Exercício Físico , Corrida de Maratona , Humanos , Masculino , Pessoa de Meia-Idade , Atletas , Exercício Físico/efeitos adversos , Corrida
12.
Int. j. morphol ; 41(6): 1673-1678, dic. 2023. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1528800

RESUMO

SUMMARY: In the sports field, sports are usually classified according to the predominance of the energy system used during the competition; sports like Crossfit and ultra-marathon could be totally opposite due to the needs of athletes to achieve good places. Due to the above, the objective was established to compare the dermatoglyphic profiles of CrossFit and Ultra-marathon athletes according to the predisposition of the energy systems, aerobic and anaerobic, used in the competitions. Cross-sectional descriptive study, where the dermatoglyphic profile of 21 athletes of national presence (10 crossfit and 11 ultra-marathon runners) was determined, through the Computerized Dermatoglyphic System, brand Salus Dermatoglifia, according to the Cummins and Midlo protocol, which consists of taking the fingerprints of the 10 fingers of the hands. The fingerprint designs of the human being (arch, loop and whorl) and the elements contained in them (nucleus and delta) were analyzed, differences were established through the Analysis of Variance test in the SPSS V.25 statistical package. The results show significant differences between the average scores of the line count of both disciplines (108 and 165), being higher in ultra-marathon runners, associated with greater aerobic resistance. Another significant and relevant finding was the presence of arch-type fingerprints only in CrossFit athletes associated, along with low line count, with strength and power. It is concluded that Crossfit and Ultra-marathon athletes have dissimilar natural physical characteristics, which is why they participate and excel in different sports where they have enhanced their natural physical abilities through training.


En el ámbito deportivo, los deportes suelen clasificarse según el predominio del sistema energético utilizado durante la competición; Deportes como el Crossfit y la ultramaratón podrían ser totalmente opuestos debido a las necesidades de los deportistas de conseguir buenos lugares. Debido a lo anterior, se estableció como objetivo comparar los perfiles dermatoglíficos de atletas de CrossFit y Ultramaratón según la predisposición de los sistemas energéticos, aeróbico y anaeróbico, utilizados en las competencias. Estudio descriptivo transversal, donde se determinó el perfil dermatoglífico de 21 deportistas de presencia nacional (10 crossfit y 11 ultramaratonistas), a través del Sistema Dermatoglífico Computarizado, marca Salus Dermatoglifia, según el protocolo Cummins y Midlo, el cual consta de tomando las huellas dactilares de los 10 dedos de las manos. Se analizaron los diseños dactilares del ser humano (arco, asa y verticilo) y los elementos contenidos en ellos (núcleo y delta), se establecieron diferencias mediante la prueba de Análisis de Varianza en el paquete estadístico SPSS V.25. Los resultados muestran diferencias significativas entre las puntuaciones medias del recuento de líneas de ambas disciplinas (108 y 165), siendo superiores en los corredores de ultramaratón, asociado a una mayor resistencia aeróbica. Otro hallazgo significativo y relevante fue la presencia de huellas dactilares tipo arco sólo en atletas de CrossFit asociadas, junto con un bajo número de líneas, con fuerza y potencia. Se concluye que los atletas de Crossfit y Ultramaratón tienen características físicas naturales disímiles, por lo que participan y destacan en diferentes deportes donde han potenciado sus capacidades físicas naturales a través del entrenamiento.


Assuntos
Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Dermatoglifia , Atletas , Corrida de Maratona , Estudos Transversais
13.
Sci Rep ; 13(1): 18083, 2023 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-37872366

RESUMO

Few studies were developed to understand the relationship between running characteristics and motivation. The purpose of this study was to assess the relationship between running event history, running experience, and best race performances in recreational distance runners. We used a web survey to obtain information regarding running experience, racing history, and periodization training routines/exercise habits, including weekly volumes and daily mileage and duration across periods and conditions. Associations between variables were conducted with the Chi-square test (χ2; nominal scale) and Wilcoxon test. Multiple linear regression analysis and multivariate linear regression were performed. Concerning the participants' motive for exercising, a significant difference was identified between the race distance subgroups (p < 0.001), where 58% of M/UM runners exercised for performance (n = 38) and 64% of HM runners (n = 57) and 57% of 10 km runners (n = 52) exercised for recreational purposes. A significant difference was found in the number of years of running completed without taking a break (p = 0.004), with marathoners/ultramarathoners reporting the most years. Runners competing in different race distances such as 10 km, half-marathon, marathon, and ultra-marathon presented differences in training background and habits according to the distance of preference.


Assuntos
Estado Nutricional , Corrida , Humanos , Corrida de Maratona , Motivação , Inquéritos e Questionários , Resistência Física
14.
Prehosp Disaster Med ; 38(5): 617-621, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37787410

RESUMO

INTRODUCTION: In recent years, unmanned aerial vehicles (UAVs) have been increasingly used for medical surveillance purposes in mass-gathering events. No studies have investigated the reliability of live video transmission from UAVs for accurate identification of distressed race participants in need of medical attention. The aim of this study was to determine the proportion of time during which live medical surveillance UAV video feed was successfully transmitted and considered of sufficient quality to identify acute illness in runners participating in the 2022 Montreal Marathon (Canada). METHODS: Four UAVs equipped with high-resolution cameras were deployed at two pre-defined high-risk areas for medical incidents located within the last 500 meters of the race. The video footage was transmitted in real-time during four consecutive hours to a remote viewing station where four research assistants monitored it on large screens. Interruptions in live feed transmission and moments with inadequate field of view (FOV) on runners were documented. RESULTS: On September 25, 2022, a total of 6,916 athletes ran during the Montreal Marathon and Half Marathon. Out of the eight hours of video footage analyzed (four hours per high-risk area), 91.7% represented uninterrupted live video feed with an adequate view of the runners passing through the high-risk areas. There was a total of 18 live feed interruptions leading to a total interruption time of 22 minutes and 19 seconds (median interruption time of 32 seconds) and eight distinct moments with inadequate FOV on runners which accounted for 17 minutes and 33 seconds (median of 1 minute 47 seconds per moments with inadequate FOV). Active surveillance of drone-captured footage allowed early identification of two race participants in need of medical attention. Appropriate resources were dispatched, and UAV repositioning allowed for real-time viewing of the medical response. CONCLUSION: Live video transmission from UAVs for medical surveillance of runners passing through higher risk segments of a marathon for four consecutive hours is feasible. Live feed interruptions and moments with inadequate FOV could be minimized through practice and additional equipment redundancy.


Assuntos
Corrida de Maratona , Dispositivos Aéreos não Tripulados , Humanos , Estudos de Viabilidade , Reprodutibilidade dos Testes , Canadá
15.
J Sports Sci Med ; 22(3): 526-531, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37711711

RESUMO

Running power output allows for controlling variables that have been previously overlooked by relying solely on speed, such as surface, gradient and weight. The ability to measure this external load variable now enables the analysis of concepts that have predominantly been studied in cycling, such as the Critical Power (CP), in the context of running. This study aims to predict the CP target at which trained athletes run a half-marathon and determine whether races of this distance can serve as a valid alternative to update the CP record. A group of nine trained athletes performed the 9/3-minute Stryd CP test and participated in a half-marathon race in two separate testing sessions conducted in the field. The average power during a half-marathon race is a valid alternative method for determining the CP in trained athletes, as evidenced by the agreement (95% CI: -0.11 to 0.37 W/kg) and trivial systematic bias (0.13 W/kg) between methods. The linear regression model half-marathon power = 0.97 + 0.75·CP (W/kg) showed low standard error of estimate (0.29 W/kg) and significant large association between methods (r = 0.88; p = 0.002). Coaches and athletes should be aware that the CP target for a half-marathon race is 97.3% of the CP determined by the 9/3-minute Stryd CP test.


Assuntos
Corrida de Maratona , Corrida , Humanos , Atletas , Conscientização , Ciclismo
16.
Int J Sports Physiol Perform ; 18(12): 1420-1426, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37734742

RESUMO

PURPOSE: Advanced footwear technology is prevalent in distance running, with research focusing on these "super shoes" in competitive athletes, with less understanding of their value for slower runners. The aim of this study was to compare physiological and biomechanical variables between a model of super shoes (Saucony Endorphin Speed 2) and regular running shoes (Saucony Cohesion 13) in recreational athletes. METHODS: We measured peak oxygen uptake (VO2peak) in 10 runners before testing each subject 4 times in a randomly ordered crossover design (ie, Endorphin shoe or Cohesion shoe, running at 65% or 80% of velocity at VO2peak [vVO2peak]). We recorded video data using a high-speed camera (300 Hz) to calculate vertical and leg stiffnesses. RESULTS: 65% vVO2peak was equivalent to a speed of 9.4 km·h-1 (0.4), whereas 80% vVO2peak was equivalent to 11.5 km·h-1 (0.5). Two-way mixed-design analysis of variance showed that oxygen consumption in the Endorphin shoe was 3.9% lower than in the Cohesion shoe at 65% vVO2peak, with an interaction between shoes and speed (P = .020) meaning an increased difference of 5.0% at 80% vVO2peak. There were small increases in vertical and leg stiffnesses in the Endorphin shoes (P < .001); the Endorphin shoe condition also showed trivial to moderate differences in step length, step rate, contact time, and flight time (P < .001). CONCLUSIONS: There was a physiological benefit to running in the super shoes even at the slower speed. There were also spatiotemporal and global stiffness improvements indicating that recreational runners benefit from wearing super shoes.


Assuntos
Endorfinas , Corrida , Humanos , Fenômenos Biomecânicos , Corrida de Maratona , Corrida/fisiologia , Sapatos , Estudos Cross-Over
17.
J Sci Med Sport ; 26(10): 506-513, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37730468

RESUMO

OBJECTIVES: To analyze the long-term effect of multiple marathons on cardiac structure and function in amateur marathon runners compared with healthy controls. DESIGN: Cross-sectional study using male amateur marathon runners (n = 32) and age-matched cohort of male healthy controls (n = 12). METHODS: A total of 32 male amateur marathon runners (age 44 ±â€¯7 years) and 12 male healthy controls (age 42 ±â€¯8 years) underwent cardiac magnetic resonance (CMR). The relevant parameters of cardiac structure and function were studied employing feature-tracking strain analysis. RESULTS: Amateur marathon runners showed lower heart rates, body mass index and body surface area. The left ventricular (LV) mass index, LV end-diastolic volume index and right ventricular end-systolic volume index were significantly higher in amateur marathon runners compared with healthy controls. Furthermore, walls of interventricular septum (IVS) in amateur marathon runners were thicker than healthy controls. There was no significant difference between two groups in the global myocardial strain (MS) in LV. However, the segmental radial and circumferential strains of the LV were lower in amateur marathon runners compared to healthy controls, specifically in the 8th and 9th segments. Finally, we also found as the total running intensity increased, so did global longitudinal strain. CONCLUSIONS: We reported higher wall thickness and lower regional radial and circumferential strain in the IVS region in amateur marathon runners, suggesting that prolonged and high-intensity exercise may cause cardiac remodeling. Further studies are needed to investigate whether this is an adaptive or maladaptive change in amateur marathon runners.


Assuntos
Corrida , Septo Interventricular , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Corrida de Maratona , Estudos Transversais , Corrida/fisiologia , Espectroscopia de Ressonância Magnética , Função Ventricular Esquerda/fisiologia
18.
J Sci Med Sport ; 26(11): 566-573, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37777396

RESUMO

OBJECTIVES: To assess how biomarkers indicating central nervous system insult (neurobiomarkers) vary in peripheral blood with exertional-heat stress from prolonged endurance exercise. DESIGN: Observational study of changes in neuron specific enolase (NSE), S100 calcium-binding protein B (S100ß), Glial Fibrillary Acid Protein (GFAP) and Ubiquitin carboxyl-terminal hydrolase isozyme L1 (UCHL1) at Brighton Marathon 2022. METHODS: In 38 marathoners with in-race core temperature (Tc) monitoring, exposure (High, Intermediate or Low) was classified by cumulative hyperthermia - calculated as area under curve of Time × Tc > 38 °C - and also by running duration (finishing time). Blood was sampled for neurobiomarkers, cortisol and fluid-regulatory stress surrogates, including copeptin and creatinine (at rested baseline; within 30 min of finishing; and at 24 h). RESULTS: Finishing in 236 ±â€¯40 min, runners showed stable GFAP and UCH-L1 across the marathon and next-day. Significant (P < 0.05) increases from baseline were shown post-marathon and at 24 h for S100ß (8.52 [3.65, 22.95] vs 39.0 [26.48, 52.33] vs 80.3 [49.1, 99.7] ng·L-1) and post-marathon only for NSE (3.73 [3.30, 4.32] vs 4.85 [4.45, 5.80] µg·L-1, P < 0.0001). Whilst differential response to hyperthermia was observed for cortisol, copeptin and creatinine, neurobiomarker responses did not vary. Post-marathon, only NSE differed by exercise duration (High vs Low, 5.81 ±â€¯1.77 vs. 4.69 ±â€¯0.73 µg·L-1, adjusted P = 0.0358). CONCLUSIONS: Successful marathon performance did not associate with evidence for substantial neuronal insult. To account for variation in neurobiomarkers with prolonged endurance exercise, factors additional to hyperthermia, such as exercise duration and intensity, should be further investigated.


Assuntos
Temperatura Corporal , Corrida , Humanos , Corrida de Maratona , Creatinina , Hidrocortisona , Corrida/fisiologia , Biomarcadores
19.
Wilderness Environ Med ; 34(4): 509-512, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37586946

RESUMO

INTRODUCTION: The importance of providing wet bulb globe temperature (WBGT) heat stress flag category measurements in real time is well recognized by road race directors, and it is bound to become even more important with the rise of extreme weather and pandemic outbreaks. The purpose of this paper is to describe the WBGT index and its components measured during the 125th running of the Boston Marathon on October 11, 2021, for qualitative comparison to measurements made similarly on its traditional April date, 2014 to 2019. METHODS: Monitoring occurred at the 7 km, 18 km, and 32 km marks of the race in the towns of Ashland, Natick-Wellesley, and Newton. The outdoor WBGT index was calculated from direct hourly measurements of the dry bulb, black globe, and natural wet bulb temperatures from 0900 to 1500 h. RESULTS: The WBGT index was not different among towns; thus, the average hourly values for the 3 towns were compared to historical data averaged identically. Although the black globe temperature fluctuated considerably in response to changing cloud cover, on average, partly cloudy skies kept the solar load comparable to what has been observed in April. Dry bulb and wet bulb temperatures were higher than those on most April dates shown, which resulted in a yellow (or amber) flag day for most of the race. CONCLUSIONS: The historic October Boston Marathon was among the warmest in recent history. Like the impact of COVID-19 on the 2021 Boston Marathon, future climate challenges around outdoor activities could necessitate rescheduling; they underscore the importance of real-time WBGT index measures.


Assuntos
Transtornos de Estresse por Calor , Corrida , Humanos , Temperatura , Estações do Ano , Corrida de Maratona , Boston , Temperatura Alta
20.
Acta Biomed ; 94(S1): e2023224, 2023 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-37606057

RESUMO

We report the case of a 52-year-old marathon runner admitted to our emergency department for exertional heat stroke (EHS). The electrocardiogram (ECG) showed a supraventricular tachycardia, probably an atrial flutter with 2:1 block, conducted with left bundle branch block. After 10 minutes of aggressive fluid management and rapid external cooling, the ECG returned to normal. As the high-sensitivity cardiac troponin I was elevated, coronary angiography and an electrophysiological study were performed, revealing normal coronary arteries and excluding inducible arrhythmias. As reported in the current literature, our findings confirm that the electrocardiographic changes and elevation of cardiac markers in EHS do not reflect cardiac ischemia, but rather a myocardial injury due to the pathophysiological response to dehydration and hyperthermia, which markedly impaired stroke volume and cardiac output. EHS is a life-threatening condition with a complex pathophysiology caused by thermoregulatory failure. Diagnosis is not always straightforward, but early recognition and timely management (the "golden hour") with rapid cooling and intravenous fluids are crucial to prevent irreversible and fatal organ damage. EHS is defined by a rectal temperature > 40.5 °C with symptoms or signs of neurological dysfunction, such as confusion, drowsiness, or seizures, which can rapidly worsen with delirium, coma, and cardiac arrest. With this case report, we want to remind emergency physicians that early diagnosis and appropriate management of EHS can avoid death and inappropriate treatment. (www.actabiomedica.it).


Assuntos
Golpe de Calor , Taquicardia Supraventricular , Humanos , Pessoa de Meia-Idade , Bloqueio de Ramo , Corrida de Maratona , Taquicardia Supraventricular/complicações , Taquicardia Supraventricular/diagnóstico , Golpe de Calor/complicações , Golpe de Calor/diagnóstico , Golpe de Calor/terapia , Febre
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...